220v 1.1Gal(5000ml) Stirring digital display thermostatic heating sleeve
I. Introduction
Designing by European techniques, with its advance technology, stable  performance, novel structure and good using effect, this equipment is  widely used for in heating in labs of colleges, petrochemical  industries, medicine, and environment protection institutions etc.
Ⅱ. Characteristics
1.
Cold  rolling sheet stretching and spraying exterior.
2.
Use  advanced digital temperature control system can precisely control the  temperature of the heated liquid, easy to use, high precision,  temperature display intuitive.
3.
Using  high quality nickel-chrome heating resistance wire sealed in high  temperature insulation layer. Woven into half the ball in heating sets,  with characteristics of large heating area, fast warm-up, high  temperature evenness, no open flame and so on.
Ⅲ. Working condition
Ambient temperature: 5~40℃;
Ambient humidity:

90%;
Voltage:
22
0
V
Ⅳ.Main technical parameters
Model
98-II-C
Capacity (ml)
50
100
250
500
1000
2000
3000
5000
Voltage(v)
110V/
22
0V
Max. use tem.
450℃
Tem. Range
Ambient tem.~40℃
Sensor
PT100
Working mode
continuous
Power(W)
80
100
150
250
350
450
600
800
(Red color is  available)
Ⅴ. Operation instruction
a)
Place  the equipment on level worktable
,  put the sensor frame, and plug it into sensor block on the back of the  instruments
b)
Fill  a liquid container in the instrument, and set the sensor in the heated  liquid.
c)
Use  the same voltage as the machine required, and then the instrument’s  screen will display the temperature of the liquid.
d)
Set  temperature: after press “S” ,the green button “Set” indicator light,  the screen display the set temperature, and press the arrow keys to  select the temperature you want to use. After setting temperature, press  “S” to display the actual temperature.
e)
When  heated the red indicator light, lights off when not heated.
f)
When  temperature rose to the set temperature at the first time, it may be  washed for few degrees; it will stabilize down when the temperature came  down.
g)
Stirring  adjust: Adjust the stirring speed by turn the knob clockwise.
Ⅵ. Safety attentions
Connect the device to an earthed power supply to ensure safety  of machine and experiment; connect the power as the machine  required.
This  equipment is forbid to use in inflammable and explosive,  poisonous and strong corrosive experiments.
Make  sure horizontal installation.
Non-professionals  are not allowed to disassemble and repair this machine.
Pay attention to the set temperature while dealing with the  inflammable matters.
Make  sure dry the resin container, if the temperature is setting too  high by accident, the container would be dissolved and then fall  on the heater to cause fire.
Overfilled  of sample will lead to overheat of working room under parts,  which will dissolve the inflammable  material and cause fire.
While  the machine is working, don’t touch the top, window and exhaust  port of the device to protect from high-temperature burns.pan>
Read  the instruction book before operation.
Ⅶ. Usage notes
1.
Because  of the surface of heat insulation material is coated with grease, in the  first used shall first heat except when heating oil, will appear white  smoke, shut off the power  after heating to smokeless, when the  temperature come down, it can normal use
2.
When  use the instrument should pour the liquid into the container firstly,  and then put in the instrument to use.
Ⅷ. Fault analysis
Phenomenon
Causation
Treatment
No power
Poor connect of
socket
and
plug
circuit  not
closes.
Adjust the socket
and  plug
Adjust  the circuit
No heating
Heating jacket wire is broke
Chang
heating
jacket
No
temperature
control
The control panel is broke
Change
control  panel
Ⅸ. Storage and transportation
Keep it in dry and clean room with good ventilation and no corrosive  gas, prevent it from wetting by the rain and avoid violent collision in  transportation.
Item#
Description
QTY
Unit
020208
220v 5000ml Stirring digital display  thermostatic heating sleeve
1
set
新建网页 1
Shipping & Handling Details
Default  Shipping Cost or Free Shipping Information:

Default   shipping cost or free shipping service is only for the customers   from Canada or the lower 48 United States by Canada Post, USPS or   the UPS Ground. Customers from other areas or needs other shipping   ways, please contact us.

Buyers   from Guam, Puerto Rico, Virgin Islands, American Samoa, Alaska,   Hawaii, PO Boxes, APO/FPO addresses or other countries/areas, there   WILL be extra shipping costs, please contact us for more detailed   information.

Please   make sure your address is valid for both UPS and USPS services. Any   costs incurred because of incorrect or undeliverable address should   be undertaken by buyer.
Handling Time:
Shipping   is usually made in 1-3 business days after payments cleared. Orders   are processed from Monday-Friday; Not on the weekends & public   holidays.
Sales tax / Customs  duties:
Any   sales taxes or Customs duties are not included. If came out, they   must be undertaken by the buyer.
Damage In Shipping:
Email  or call us First! We will work  with you to get the case resolved in  the fastest method.
Return /  Refund
If you are not 100% happy  with your purchase, please  contact Us. Please don't directly opened  a request or case without  informing us, or else, we will do some  discounts on the warranty and  other sales-services later on. Hope  for your understanding.
Returns & Exchanges

All   returns must be made within 14 days of delivery date. Items must be   in new, unused condition, with all original materials included with   the shipment. A partial refund may be applied for opened or damaged   items, depending on the condition.

Items   returned under the buyer’s remorse: The return shipping fee must be   covered by the buyer; The original shipping cost will also be   deducted from the refund. 15% restocking fee of the items purchase   price will be charged.

Returns   that are the result of our seller's error: Buyer will receive a  full  refund of the item as well as shipping charges

All   returns require a RA (Return Authorization) number that will be   given by our seller. Please contact with us at first for more   details.
Defective & Damaged  Products

If   product was received damaged or not as described, please send us   some pictures or videos, so we could well understand your problem,   then solve them for you ASAP. Besides, it's much helpful for us to   claim with UPS, remind our related department to pay much more   attention to packaging later on. Hope for your understanding.

Replacement   or refund of defective or damaged products can only be returned in   exchange for the exact same product, or else, the purchase price   will be refunded back to your original payment method.

If   an item is received damaged, customer service must be contacted   within 7 days of receiving your item. All returns require a RA   (Return Authorization) number as above.
Payment
eCheck Issues:
Payments  via  eCheck do not clear immediately. Usually you will wait 5-7  days  after checkout for it to clear. Then we will arrange  shipments  for you.
Warranty & Feedback

6   months' warranty for the machines, not for the consumables. We  stand  behind our products all the item, so even if your warranty  period  has expired, you can still seek for service or technical  support  from us with low cost.

Any   warranty shipping cost to us is responsible by buyer.

Any   shipping cost to buyer is responsible by the seller.

We   committee to the customer satisfaction and want to bring you the   best purchase experience. If there is any problems, please contact   us ASAP. If not, please leave us a positive feedback as it's very   important for us. Thanks very much.